Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
J Clin Exp Dent ; 16(3): e257-e262, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38600923

RESUMO

The present study aimed to evaluate the accuracy of four different Electronic Foraminal Locators (EFLs): Root ZX II (J. Morita, Tokyo, Japan), RomiApex A15 (Romidan, Kiryat-Ono, Israel), FinePex (Schuster, Porto Alegre, Brazil) and VDW Gold (VDW, Munich, Germany), in determining root length during endodontic retreatment steps. Twenty-seven human unirooted teeth had their crowns sectioned to standardize the teeth to 17 mm. The actual tooth length was visualized with an operating microscope and a #15 file juxtaposed to the apical foramen. Teeth were instrumented with files R25 and R40, and at the end of each instrumentation, measurements of root canal lengths were made with files #25 and #40. Then, the teeth had their root canals filled with standardized Gutta-Percha R40 cones and Endofill cement, and after seven days, they were uncovered with R25 and R40 files, respectively. New measurements were made with #25 and #40 files between the uncovering with each file. The data were statistically analyzed by ANOVA and Chi-square tests, considered significant when P<0.05. All devices tended to under-measurement when the obturating material was partially removed with the R25 file. When the canals were uncovered with the R40 instrument, the effectiveness of the appliances increased significantly (P<0.05). At 0.40 mm diameter, the mean accuracy of the Romiapex A15 appliance was statistically lower than the other EFLs (P<0.001), showing a tendency to over-measurement. In conclusion, all the tested appliances showed similar efficacy when acceptable limits were observed. The permanence of the remaining filling material in the apical third influenced the accuracy and efficacy of EFLs in endodontic retreatment cases. Key words:Endodontics, odontometry, apical foramen.

2.
Braz Dent J ; 35: e245611, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38537014

RESUMO

This study evaluated the correlation between root canal curvature and the effects of ultrasonic irrigation in the following parameters: volume of uncontrolled dentin removal (UDRVol), maximum depth of dentin defects, removal of accumulated hard tissue debris (AHTD), and canal transportation in prepared curved root canals. Twenty-four human permanent mandibular molars were divided into two groups according to root canal curvature: moderate curvature (MC: mean 25°); and severe curvature (SC: mean 48°). The specimens were scanned using an X-ray microcomputed scanner (Skyscan 1172) before and after cleaning and shaping and after the final irrigation protocol with ultrasonic irrigation. There was a moderate correlation between the degree of root canal curvature and the volume of remaining AHTD (p<0.05) and between the degree of root canal curvature and maximum depth of defects due to uncontrolled removal of dentin (p<0.05). The teeth in the SC group had a greater maximum depth of defects on the dentin wall in the apical third than the teeth in the MC group (p <0.05). Both groups had a significant reduction of AHTD in all canal thirds, but the amount of remaining AHTD in the middle and apical thirds and the whole canal was significantly greater in the SC than in the MC group (p <0.05). Canal transportation was not influenced by the canal curvature in all thirds (p >0.05). This study concluded that root canal curvature affects significantly the uncontrolled removal of dentin and remaining AHTD volume after the final irrigation protocol with ultrasonic irrigation.


Assuntos
Cavidade Pulpar , Preparo de Canal Radicular , Humanos , Preparo de Canal Radicular/métodos , Ultrassom , Irrigantes do Canal Radicular , Irrigação Terapêutica/métodos , Microtomografia por Raio-X , Dentina
3.
J Clin Exp Dent ; 16(1): e18-e24, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38314341

RESUMO

Background: To evaluate the accuracy of four different Electronic Foraminal Locators (EFLs): Root ZX II (J. Morita, Tokyo, Japan), Romiapex A15 (Romidan, Kiryat-Ono, Israel), FinePex (Schuster, Porto Alegre, Brazil), and VDW Gold (VDW, Munich, Germany), in determining root canal length. Material and Methods: Twenty-seven human single-rooted teeth had their crowns sectioned at the cementoenamel junction, and the actual length of the tooth was obtained by visualizing with an operative microscope a #15 file placed adjacent to the apical foramen. The teeth were instrumented with R25 and R40 files, and at the end of each instrumentation, measurements of the lengths of the root canals were made with #25 and #40 files. The data were statistically analyzed by ANOVA and chi-square tests and were considered significant when P<0.05. All devices showed a tendency to underestimate measurements by 0.25 mm diameter. Results: The mean accuracy of the Root ZX II appliance was statistically lower than the other EFLs (P<0.001). For the 0.40 mm diameter, the mean accuracy of the Romiapex A15 appliance was statistically higher than the other LEFs (P<0.001). However, when the diameter was 0.40 mm, only the Romiapex A15 device tended to overmeasure. Regarding the acceptable limits of variation, it was observed that the devices showed similar efficiency in determining odontometry (P>0.05), both with diameters of 0.25 mm and 0.40 mm. Conclusions: It was concluded that the devices presented similar and adequate efficacy when observing the limits of acceptable measurements. It was observed that increasing the apical diameter did not influence the accuracy of EFLs in determining root canal lengths. Key words:Endodontics, working length, electronic foraminal locators, endodontic treatment.

4.
Braz. dent. j ; 35: e24, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1550086

RESUMO

Abstract This study evaluated the correlation between root canal curvature and the effects of ultrasonic irrigation in the following parameters: volume of uncontrolled dentin removal (UDRVol), maximum depth of dentin defects, removal of accumulated hard tissue debris (AHTD), and canal transportation in prepared curved root canals. Twenty-four human permanent mandibular molars were divided into two groups according to root canal curvature: moderate curvature (MC: mean 25°); and severe curvature (SC: mean 48°). The specimens were scanned using an X-ray microcomputed scanner (Skyscan 1172) before and after cleaning and shaping and after the final irrigation protocol with ultrasonic irrigation. There was a moderate correlation between the degree of root canal curvature and the volume of remaining AHTD (p<0.05) and between the degree of root canal curvature and maximum depth of defects due to uncontrolled removal of dentin (p<0.05). The teeth in the SC group had a greater maximum depth of defects on the dentin wall in the apical third than the teeth in the MC group (p <0.05). Both groups had a significant reduction of AHTD in all canal thirds, but the amount of remaining AHTD in the middle and apical thirds and the whole canal was significantly greater in the SC than in the MC group (p <0.05). Canal transportation was not influenced by the canal curvature in all thirds (p >0.05). This study concluded that root canal curvature affects significantly the uncontrolled removal of dentin and remaining AHTD volume after the final irrigation protocol with ultrasonic irrigation.


Resumo Este estudo avaliou a correlação entre a curvatura do canal radicular e os efeitos da irrigação ultrassônica nos seguintes parâmetros: volume de remoção não controlada de dentina (UDRVol), profundidade máxima do desgaste de dentina, remoção de debris de tecido duro acumulado (AHTD) e transporte em canais radiculares curvos. Vinte e quatro molares inferiores humanos permanentes foram divididos em dois grupos de acordo com a curvatura do canal radicular: curvatura moderada (MC: média de 25°); e curvatura acentuada (SC: média de 48°). Os espécimes foram digitalizados usando um scanner microcomputador de raios X (Skyscan 1172) antes e depois da limpeza e modelagem e após a irrigação ultrassônica. Houve uma correlação moderada entre o grau de curvatura do canal radicular e o volume de AHTD remanescente (p<0,05) e entre o grau de curvatura do canal radicular e a profundidade máxima de defeitos devido à remoção descontrolada de dentina (p<0,05). Os dentes do grupo SC apresentaram maior profundidade máxima de defeitos na parede dentinária no terço apical do que os dentes do grupo MC (p<0,05). Ambos os grupos tiveram uma redução significativa de AHTD em todos os terços do canal, mas a quantidade de AHTD remanescente nos terços médio e apical e em todo o canal foi significativamente maior no grupo SC do que no grupo MC (p <0,05). O transporte do canal não foi influenciado pela curvatura do canal em todos os terços (p > 0,05). Este estudo concluiu que a curvatura do canal radicular afeta significativamente a remoção descontrolada de dentina e o volume remanescente de AHTD após a irrigação ultrassônica.

5.
J Clin Exp Dent ; 15(11): e938-e944, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38074173

RESUMO

Background: This study aimed to assess the knowledge of Brazilian endodontists regarding the use of cone beam computed tomography (CBCT) in endodontic therapy. Material and Methods: An invitation to participate in the research was sent to 3256 professionals through class groups on social networks and via email. Participants answered an online questionnaire consisting of 11 questions about the clinical situations in which they used CBCT and whether they had any knowledge of the technical protocols such as parameters of field of view (FOV) and voxels of the CBCT equipment. The questionnaire was answered by 742 endodontists who represented 22.7% of the invited professionals. Results: The data obtained indicate that 76.7% of the participants use or have used CBCT during endodontic treatments. The most often reported clinical conditions for using the CBCT were: root fractures (64%), locating the canals (58.7%), perforations (53.9%), and root resorption (42.1%). More than 60% of the participants stated that they do not have information about the voxel, FOV, and the CBCT system used in their requests. Only 34.1% reported using CBCT to the performed endodontic treatments follow-up. Conclusions: CBCT was a tool widely utilized by the participants, with root fracture being the clinical condition with the highest indication for CBCT. Many professionals were unaware of the technical protocol used in the exams. Key words:Endodontics, Cone Beam Computed Tomography, Endodontic Therapy.

6.
Braz Dent J ; 34(3): 25-32, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37466522

RESUMO

This study aimed to evaluate the tissue repair capacity of four bioceramic endodontic sealers by quantifying type I and III collagen fibers. The following sealers were tested: EndoSequence BC Sealer (Brasseler, Brasseler, Savannah, USA), Bio C Sealer (Angelus, Londrina, Brazil), Bioroot RCS (Septodont, Santa Catarina, Brazil), and Sealer Plus BC (MKLife, Porto Alegre, Brazil). Polyethylene tubes 1.5 mm in diameter and 1 cm in length containing the endodontic sealers were implanted in the subcutaneous tissue of five rats (Rattus norvegicus albinus, Wistar lineage). After 14 days, the animals were euthanized, and collagen fibers were quantified from the histological tissue sections. Given a non-normal distribution of the data, a gamma regression with log link function was employed and implemented through the generalized linear models module, was used to test whether there was a significant difference between the sealers. The pairwise comparison was performed using Least significant difference. There were significant differences between the sealers for type I (p=0.001), type III (p=0.023), and total collagen (p=0.002). Overall, Bioroot sealer was statistically superior to the other sealers, except in the analysis of type III collagen, in which there was no difference between the Bioroot sealer and Bio C Sealer sealer and the control group (p>0.05). Bioroot RCS bioceramic endodontic sealer stimulates a greater production of collagen.


Assuntos
Materiais Restauradores do Canal Radicular , Ratos , Animais , Resinas Epóxi , Compostos de Cálcio , Tela Subcutânea , Teste de Materiais , Ratos Wistar , Silicatos , Colágeno
7.
Restor Dent Endod ; 48(2): e17, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37284340

RESUMO

The present report describes the endodontic treatment of an Oehlers type II dens invaginatus in a maxillary lateral incisor with 5 root canals, an extremely rare condition. Apical periodontitis and related symptoms were noted. Cone-beam computed tomography was used to aid the diagnosis, reveal tooth morphology, and assist in canal location. The pulp chamber was carefully accessed, and the root canals were explored under magnification. All root canals were prepared with an R25 Reciproc Blue system and sodium hypochlorite (NaOCl) irrigation. After initial preparation, a self-adjusting file (SAF) with NaOCl and ethylenediaminetetraacetic acid was used to complement the disinfection. Additionally, calcium hydroxide medication was applied. Vertical compaction was used to fill the canals with a calcium silicate-based endodontic sealer and gutta-percha. After 12 months, the patient exhibited healing of the periapical region, absence of symptoms, and normal dental function. In conclusion, this nonsurgical treatment protocol was successful in promoting the cure of apical periodontitis. Both complementary disinfection with an SAF and use of calcium hydroxide medication should be considered when choosing the best treatment approach for dens invaginatus with very complex anatomy.

8.
Braz. dent. j ; 34(3): 25-32, May-June 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1447604

RESUMO

Abstract This study aimed to evaluate the tissue repair capacity of four bioceramic endodontic sealers by quantifying type I and III collagen fibers. The following sealers were tested: EndoSequence BC Sealer (Brasseler, Brasseler, Savannah, USA), Bio C Sealer (Angelus, Londrina, Brazil), Bioroot RCS (Septodont, Santa Catarina, Brazil), and Sealer Plus BC (MKLife, Porto Alegre, Brazil). Polyethylene tubes 1.5 mm in diameter and 1 cm in length containing the endodontic sealers were implanted in the subcutaneous tissue of five rats (Rattus norvegicus albinus, Wistar lineage). After 14 days, the animals were euthanized, and collagen fibers were quantified from the histological tissue sections. Given a non-normal distribution of the data, a gamma regression with log link function was employed and implemented through the generalized linear models module, was used to test whether there was a significant difference between the sealers. The pairwise comparison was performed using Least significant difference. There were significant differences between the sealers for type I (p=0.001), type III (p=0.023), and total collagen (p=0.002). Overall, Bioroot sealer was statistically superior to the other sealers, except in the analysis of type III collagen, in which there was no difference between the Bioroot sealer and Bio C Sealer sealer and the control group (p>0.05). Bioroot RCS bioceramic endodontic sealer stimulates a greater production of collagen.


Resumo Este estudo visou avaliar a capacidade de reparação de tecidos de quatro cimentos endodônticos biocerâmicos através da quantificação de fibras colágenas de tipo I e III. Foram testados os seguintes cimentos: EndoSequence BC Sealer (Brasseler, Brasseler, Savannah, EUA), Bio C Sealer (Angelus, Londrina, Brasil), Bioroot RCS (Septodont, Santa Catarina, Brasil), e Sealer Plus BC (MKLife, Porto Alegre, Brasil). Foram implantados tubos de polietileno de 1,5 mm de diâmetro e 1 cm de comprimento contendo os cimentos endodônticos no tecido subcutâneo de cinco ratos (Rattus norvegicus albinus, linhagem Wistar). Após 14 dias, os animais foram eutanasiados e as fibras colágenas foram quantificadas a partir de cortes histológicos do tecido. Diante de uma distribuição não-normal dos dados, uma regressão gama com função de ligação log, implementada por meio do módulo de modelos lineares generalizados, foi empregada para testar se havia diferença significativa entre os cimentos. A comparação dois a dois foi realizada utilizando Least significant difference. Houve diferença significativa entre os cimentos para os colágenos tipo I (p=0,001), tipo III (p=0,023) e colágeno total (p=0,002). No geral, o cimento Bioroot foi estatisticamente superior aos demais cimentos, com exceção na análise do colágeno tipo III na qual não houve diferença entre o cimento Bioroot e o cimento Bio C Sealer e o grupo controle (p>0,05). O cimento endodôntico biocerâmico Bioroot RCS foi capaz de estimular uma maior produção de colágeno.

9.
J Dent Educ ; 86(6): 751-758, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35061917

RESUMO

OBJECTIVES: The aim of this cross-sectional retrospective study was to evaluate radiographically the technical quality of root canal treatment performed by undergraduate students using reciprocating NiTi instrumentation and single-cone obturation. METHODS: Endodontic treatment on 1102 teeth performed by undergraduate students from the School of Dentistry of the University of Santa Cecilia (Brazil) was evaluated. All root canal preparations were performed using Reciproc files and were irrigated with 1% NaOCl. The root canal was filled with gutta-percha, along with AH Plus sealer, using the single-cone obturation technique. The technical quality of the root canal treatment was evaluated based on immediate postoperative radiographs. Distance between the end of the filling and the radiographic apex, the filling density, and the taper of the root filling was assessed. Inter-examiner agreement statistic (Kappa) and Chi-square statistic test were used for statistical evaluation of the results. Differences were considered statistically significant when p < 0.05. RESULTS: Anterior teeth, maxillary premolars, and molars presented better results than mandibular premolars and molars (p < 0.05). Mandibular premolars presented a high incidence of a short length of obturation (33.34%) and mandibular molars presented a high incidence of overfilling (6.55%). The majority of the treatment analyzed (62.46%) fulfilled all the criteria showing acceptable working length, taper, and density of obturation. Instrument fractures occurred in eighteen root canals (0.81%). CONCLUSIONS: The use of NiTi reciprocating instruments with the single-cone obturation technique provided an acceptable quality of endodontic treatment in the majority of the cases performed by undergraduate students.


Assuntos
Materiais Restauradores do Canal Radicular , Obturação do Canal Radicular , Estudos Transversais , Cavidade Pulpar , Humanos , Estudos Retrospectivos , Materiais Restauradores do Canal Radicular/uso terapêutico , Obturação do Canal Radicular/métodos , Preparo de Canal Radicular , Estudantes
10.
J Contemp Dent Pract ; 23(10): 979-983, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37073909

RESUMO

AIM: This study aimed to evaluate the spatial location of the second mesiobuccal canal (MB2) of maxillary molars (MMs), using cone-beam computed tomography (CBCT), in a Brazilian subpopulation. MATERIALS AND METHODS: The CBCT examination of 250 patients performed on the Eagle 3D device was analyzed, totaling 787 MMs. Using the Radiant Dicom Viewer software, measurements were made of the distances, in millimeters (mm), between the first mesiobuccal canal (MB1), MB2, and palatal (P) canal inputs, from the axial sections. The Image J software evaluated the angle formed by the lines. The data obtained were analyzed statistically by Fisher's exact and Chi-square tests with a significance of 5%. RESULTS: The prevalence of MB2 canals observed was 76.44 and 41.73% in the first and second molars (1MMs and 2MMs), respectively (p < 0.05). The average of the distances and angles performed, for the location of the MB2 canals of the analyzed teeth, were MB1-P = 5.83 mm, MB1-MB2 = 2.31 mm, and MB2 for the intersection of the connecting distance from MB2-T = 0.90 mm. The average angle formed between the MB1-P and MB1-MB2 distances was 25.89° and 19.68° for the 1MMs and 2MMs, respectively. It was also observed that 91.4 and 75.4% of the maxillary 1MMs and 2MMs, respectively, presented the MB2 canals mesially located at the line connecting the MB1-P canals (p < 0.0001). CONCLUSION: The MB2 canals were located mesially to the MB1 canal with an average distance of 2 mm between the canals. CLINICAL SIGNIFICANCE: The anatomical knowledge of the spatial location of the MB2 canal in different ethnicities is important for the planning and execution of endodontic treatment.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Dente Molar , Humanos , Brasil , Dente Molar/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/métodos , Cavidade Pulpar/diagnóstico por imagem , Maxila/diagnóstico por imagem
11.
Aust Endod J ; 47(3): 544-549, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33913601

RESUMO

This study evaluated the resistance to flexural fatigue and torsional strength of files for glide path preparation in continuous rotation or Optimum Glide Path motion (OGP). ScoutRace 15.02 and ProGlider 16.02 files were used in a dynamic testing device during preparation of simulating curved root canals (40-degree curvature and 5 mm radius). For the torsional test, a machine was used to test torsion measured maximum torsional strength (N.cm). Two-way anova and Tukey's multiple comparisons test were used for statistical analysis. Files in OGP motion had a statistically better resistance to flexural fatigue (P < 0.05). ProGlider files took longer time to failure than ScoutRace files only when OGP was used (P < 0.05). The torsional test revealed that OGP produced significantly less torsional stress than rotary motions for both types of glide path files (P < 0.05) In conclusion, OGP motion increased substantially the mechanical safety of endodontic glide path files.


Assuntos
Esportes , Projetos de Pesquisa
12.
Braz Oral Res ; 34: e117, 2020 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-32901732

RESUMO

The aim of this study was to assess Brazilian endodontists' level of knowledge about the coronavirus disease (COVID-19) and examine its professional repercussions. The link to the online survey that was created for this study was shared with Brazilian endodontists through social networking applications. The questionnaire contained questions that pertained to COVID-19 and its impact on dental practice. The collected data were analyzed using t-test, chi-square analysis, and analysis of variance, and the level of significance was set at 0.05. A total of 2,135 participants responded to the questionnaire, and all five Brazilian regions were represented in the sample. A total of 98.50% of endodontists reported that dental procedures can transmit COVID-19. Complete social distancing was practiced by 96.68% of the participants, and approximately 25% knew someone who had COVID-19. Moreover, in their daily practice, 72.13% of them implemented biosecurity measures that are ineffective in preventing COVID-19. Furthermore, 91.7% of them reportedly suspended elective dental procedures. Only 55.69% of them reported that they performed only emergency procedures in their workplaces. Those who believed that COVID-19 cannot be transmitted during dental procedures were less knowledgeable about the symptoms of COVID-19 (p = 0.0095). Endodontists who believed that personal protective equipment cannot prevent contamination were more knowledgeable about the symptoms of COVID-19 than their counterparts (p = 0.0003). The participating Brazilian endodontists demonstrated adequate knowledge about the risk of contamination during dental procedures and the main symptoms of COVID-19. Only some professionals reported providing emergency dental care during the pandemic.


Assuntos
Infecções por Coronavirus/epidemiologia , Endodontistas , Conhecimentos, Atitudes e Prática em Saúde , Pneumonia Viral/epidemiologia , Betacoronavirus , Brasil , COVID-19 , Infecções por Coronavirus/transmissão , Endodontia , Humanos , Pandemias , Pneumonia Viral/transmissão , SARS-CoV-2 , Inquéritos e Questionários
13.
Aust Endod J ; 46(3): 381-386, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32820589

RESUMO

This paper aims to report a case in which central giant cell granuloma (CGCG) mimicked a periapical lesion of endodontic origin. An 18-year-old female patient was referred for diagnosis and treatment of extensive radiolucent periapical lesion involving 31, 32, 33, 34 and 35 teeth. Clinically, the patient presented slight facial asymmetry and healthy teeth on the affected side with positive response to thermal vitality tests. Thus, an incisional biopsy was performed, which presented a histopathological picture characteristic of a CGCG. The endodontic treatment of the involved teeth was followed by surgical curettage of the lesion. After two years of follow-up, the patient was asymptomatic, with marked improvement in mandibular symmetry and adequate healing of the lesion. Therefore, the diagnosis of radiolucent periapical lesions must include lesions of endodontic and non-endodontic origin for better treatment planning and execution.


Assuntos
Granuloma de Células Gigantes , Adolescente , Diagnóstico Diferencial , Feminino , Granuloma de Células Gigantes/diagnóstico por imagem , Granuloma de Células Gigantes/cirurgia , Humanos
14.
Dent. press endod ; 10(2): 42-47, maio-ago.2020. Tab, Ilus
Artigo em Inglês | LILACS | ID: biblio-1344547

RESUMO

Objetivo: O objetivo do presente estudo foi avaliar a influência da liga (NiTi convencional e M-Wire) e do movimento (reciprocante e rotação contínua) na resistência à fadiga cíclica. Métodos: Quinze limas Reciproc R25 (VDW GmbH, Munique, Alemanha) foram usadas em movimento reciprocante (MR), enquanto trinta limas Mtwo 25.07 (VDW GmbH, Munique, Alemanha) foram usadas em MR (n=15) ou em rotação contínua (RC) (n=15). Os instrumentos foram submetidos a ensaios dinâmicos movidos por motor elétrico, que permitiram reproduzir o movimento de pecking motion, a 300rpm de velocidade. Os instrumentos simularam a instrumentação de um canal radicular curvo com 40o e 5mm de raio de curvatura. A fratura dos instrumentos foi detectada por um sensor digital, e o tempo e o número de ciclos foram registrados. Os dados foram analisados estatisticamente pelos testes ANOVA e de Tukey (p<0,05). Resultados: Os instrumentos Reciproc R25 movidos por MR alcançaram número significativamente maior (p<0,05) de ciclos antes da fratura (1.777,68±334,2 ciclos), quando comparados aos instrumentos MT 25.07 movidos por MR (610,67±126,3 ciclos) ou RC (432,23±183,2 ciclos). Conclusões: O movimento reciprocante mostrou resistência à fadiga cíclica significativamente maior, e os instrumentos de NiTi M-Wire apresentaram maior resistência à fadiga cíclica do que os instrumentos rotatórios de NiTi convencional (AU).


Objective: The aim of present study was to evaluate the influence of alloy (conventional NiTi and M-Wire NiTi) and movement (reciprocating movement and continuous rotation) on resistance to cyclic fatigue. Methods: Fifteen Reciproc R25 files (VDW GmbH, Munich, Germany) were used in reciprocation motion (RM), while thirty MTwo 25/.07 files (VDW GmbH, Munich, Germany) were used either in RM (n=15) or in continuous rotation (CR) (n=15). The files were submitted to dynamic assays device moved by electric engine that allowed the reproduction of pecking motion under 300 rpm of speed. The files act simulating the instrumentation of a curved root canal with 40º and 5-mm of curvature radius. The fracture was detected by the device sensor and the time and number of cycles were obtained. Data were statistically analyzed by ANOVA and Tukeys tests (p<0.05). Results: The Reciproc R25 instruments moved by RM reached significantly higher number (p<0.05) of cycles before fracture (1777.68 ± 334.2 cycles) when compared with MTwo 25/.07 instruments moved by RM (610.67 ± 126.3 cycles) or CR (432.23 ± 183.2 cycles). Conclusions: The reciprocation motion showed significantly greater cyclic fatigue resistance and the M-Wire NiTi files showed higher cyclic fatigue resistance than conventional NiTi rotary files (AU).


Assuntos
Rotação , Instrumentos Odontológicos , Endodontia , Fadiga
15.
Dent. press endod ; 10(2): 29-33, maio-ago.2020. Tab
Artigo em Inglês | LILACS | ID: biblio-1344315

RESUMO

Objetivo: O presente estudo teve como objetivo comparar três sistemas de instrumentação de NiTi, tratados termicamente, quanto ao número de condutos instrumentados até a fratura. Métodos: Foram utilizados 210 molares humanos inferiores e superiores com curvaturas leves a moderadas, comprimentos reais entre 19 e 21 mm e forames apicais até 200µm. Esses foram randomicamente divididos em três grupos de acordo com o sistema de instrumentação utilizado: Reciproc (REC; R25), ProDesign Duo Híbrido (PDH; #25/.01 e #25/.08) e TF Adaptive (TFA; #25/.08). Foram utilizados 5 instrumentos/kits de cada sistema. Registrou-se, então, o número de condutos instrumenta- dos até a fratura e o número de reinserções necessárias até o alcance do comprimento de trabalho. Resultados: A análise estatística apontou diferenças significativas quando comparada a durabilidade dos sistemas, tendo os instrumentos do grupo PDH oferecido os maiores valores (29,2), seguido de REC (21,6) e TFA (15,4) (p<0,05). Quanto ao número de reinserções, o sistema TFA foi o que necessitou do menor número de reinserções (p<0,05). Conclusão: Nas condições do estudo, pode-se concluir que o sistema ProDesign Duo Híbrido foi o mais durável; ainda que o sistema TF Adaptive tenha alcançado o comprimento de trabalho com maior facilidade


Objective: The present study compared three systems of thermally treated NiTi endodontic files regarding their achieved number of prepared root canals before fracture. Methods: Two hundred and ten slightly and moderately curved upper and lower molars with actual length ranging from 19 to 21 mm and apex foramens diameters up to 200 µm were used. The sample was allotted to three groups according to the instrumentation system in use: Reciproc (REC; R25), ProDesign Duo Hybrid (PDH; #25/.01 and #25/.08), and TF Adaptive (TFA; #25/.08). Five instruments/kits of each system were used. Then, it was registered the number of root canals prepared until the instrument fractured and the number of reinsertions needed until the working length was achieved. Results: The statistical analysis showed significant differences among the durability of the three systems, being the instruments of group PDH the ones that yielded higher reuses (29.2) followed by groups REC (21.6), and TFA (15.4) (P < .05). Regarding the number of insertions, the TFA system was the one that needed the lowest number of reinsertions (P < .05). Conclusion: Under this study conditions, ProDesign Duo Hybrid was the most durable system, whereas TF Adaptive system was the one that most easily achieved the working length.


Assuntos
Humanos , Fraturas de Estresse , Instrumentos Odontológicos , Dente Molar
17.
Braz. oral res. (Online) ; 34: e117, 2020. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1132672

RESUMO

Abstract The aim of this study was to assess Brazilian endodontists' level of knowledge about the coronavirus disease (COVID-19) and examine its professional repercussions. The link to the online survey that was created for this study was shared with Brazilian endodontists through social networking applications. The questionnaire contained questions that pertained to COVID-19 and its impact on dental practice. The collected data were analyzed using t-test, chi-square analysis, and analysis of variance, and the level of significance was set at 0.05. A total of 2,135 participants responded to the questionnaire, and all five Brazilian regions were represented in the sample. A total of 98.50% of endodontists reported that dental procedures can transmit COVID-19. Complete social distancing was practiced by 96.68% of the participants, and approximately 25% knew someone who had COVID-19. Moreover, in their daily practice, 72.13% of them implemented biosecurity measures that are ineffective in preventing COVID-19. Furthermore, 91.7% of them reportedly suspended elective dental procedures. Only 55.69% of them reported that they performed only emergency procedures in their workplaces. Those who believed that COVID-19 cannot be transmitted during dental procedures were less knowledgeable about the symptoms of COVID-19 (p = 0.0095). Endodontists who believed that personal protective equipment cannot prevent contamination were more knowledgeable about the symptoms of COVID-19 than their counterparts (p = 0.0003). The participating Brazilian endodontists demonstrated adequate knowledge about the risk of contamination during dental procedures and the main symptoms of COVID-19. Only some professionals reported providing emergency dental care during the pandemic.


Assuntos
Humanos , Pneumonia Viral/epidemiologia , Conhecimentos, Atitudes e Prática em Saúde , Infecções por Coronavirus/epidemiologia , Endodontistas , Pneumonia Viral/transmissão , Brasil , Inquéritos e Questionários , Infecções por Coronavirus/transmissão , Endodontia , Pandemias , Betacoronavirus , SARS-CoV-2 , COVID-19
19.
Braz Oral Res ; 33: e082, 2019 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-31460608

RESUMO

The present study aimed to evaluate the internal configuration of the maxillary molars of a population from the Northeast region of Brazil. Cone-beam computed tomography (CBCT) exams from 512 patients (1501 teeth) were evaluated regarding the anatomical configuration of the root canal system, according to Vertucci's classification. The images were obtained using a Prexion 3D scanner operating at 90 kVp and 4 mA. The voxel size was 0.125 mm and the cut thickness was 1 mm. The images were then analyzed in the Prexion 3D Viewer software. The data were analyzed statistically by Pearson's chi-square test, with 5% of significance. The first and second molars presented three roots in 99.14% and 87.27% of the cases, respectively. In relation to the number of canals, the first and second molars had a significantly higher frequency of three and four root canals respectively, presenting a higher prevalence of types I and II (p < 0.001). The second mesiobuccal canal (MB2) was observed in 48.21% and 22.72% of the first and second molars, respectively (p < 0.001). The identification of the MB2 canal was greater in young and adult patients (p < 0.001), presenting a higher prevalence in male patients (p < 0.001). The internal configuration of the MB root was influenced by gender and by age, presenting a higher prevalence of the MB2 in male patients younger than 50 years of age.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Cavidade Pulpar/anatomia & histologia , Cavidade Pulpar/diagnóstico por imagem , Dente Molar/anatomia & histologia , Dente Molar/diagnóstico por imagem , Adolescente , Adulto , Distribuição por Idade , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Brasil , Criança , Feminino , Humanos , Masculino , Maxila , Pessoa de Meia-Idade , Valores de Referência , Distribuição por Sexo , Fatores Sexuais , Adulto Jovem
20.
Braz Oral Res ; 33: e049, 2019 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-31141039

RESUMO

The aim of the present study was to assess the penetration capacity of two endodontic cements, Endosequence BC Sealer and AH Plus, in artificial lateral canals. Twenty-six two-rooted, maxillary first premolars were instrumented to size 40.06 using K3 files. In each root, six lateral canals of two diameters (0.06 and 0.10 mm) were created with a working length of 2, 4, and 6 mm. The specimens were randomly divided into two groups according to the endodontic cement to be used (Endosequence BC Sealer and AH Plus) and obturated by the single-cone technique. The specimens were imaged by digital periapical radiography and scores from 0 to 4 were attributed according to the degree of penetration by sealers into the lateral canals. Data were analyzed statistically by Kruskal-Wallis and Student-Newman-Keuls tests, and a significance level of p < 0.05 was adopted. No significant difference was observed between the two endodontic cements used to fill the simulated lateral canals (p > 0.05). The diameter of lateral canals only influenced the capacity of the Endosequence BC Sealer in filling the canals, and presented greater penetration in the lateral canals of diameter 0.10 mm (p < 0.05). We concluded that the bioceramic endodontic cement Endosequence BC Sealer presented similar ability as AH Plus to fill simulated lateral canals.


Assuntos
Fosfatos de Cálcio/química , Cerâmica/química , Cavidade Pulpar/efeitos dos fármacos , Resinas Epóxi/química , Óxidos/química , Materiais Restauradores do Canal Radicular/química , Silicatos/química , Combinação de Medicamentos , Humanos , Teste de Materiais , Distribuição Aleatória , Valores de Referência , Reprodutibilidade dos Testes , Obturação do Canal Radicular/métodos , Estatísticas não Paramétricas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...